The SP11 Propane Sensor is a high-performance semiconductor gas sensor designed for accurate and reliable detection of propane (C₃H₈) across a wide concentration range. With its compact design, low power consumption, and strong anti-interference capability, the SP11 is ideal for gas leakage monitoring in homes, industrial facilities, and commercial environments.
1. Product Overview
The SP11 Propane Sensor is manufactured using multilayer thick-film technology. A micro ceramic substrate integrates both the heater and the metal oxide semiconductor (MOS) sensing layer, located on opposite sides. This assembly is enclosed in a durable metal housing to ensure long-term stability and protection.
When propane is present in the ambient air, the sensor’s conductivity changes proportionally to the gas concentration. A simple circuit can convert this conductivity variation into a readable output signal, corresponding to the detected propane level.
2. Key Features
-
Wide Detection Range: Capable of detecting propane from 0 to 10,000 ppm.
-
High Sensitivity: Sensitivity ≥ 8 (at 2500 ppm propane), ensuring fast and accurate response.
-
Excellent Anti-Interference: Reliable operation even in environments with multiple gas types.
-
Low Power Consumption: Heating power consumption ≤ 500 mW, ideal for portable and battery-powered devices.
-
Fast Response & Recovery: Real-time monitoring with quick signal stabilization.
-
Long Service Life: Durable structure designed for up to 10 years of use.
-
Cost-Effective: Simplified circuit requirements and compact packaging reduce system cost.
3. Technical Specifications
| Parameter | Value |
|---|---|
| Model | SP11 |
| Sensor Type | Semiconductor |
| Target Gas | Propane (C₃H₈) |
| Detection Range | 0 – 10,000 ppm |
| Circuit Voltage (VC) | ≤ 24V DC |
| Heater Voltage (VH) | 5V ± 0.1V DC |
| Load Resistance (RL) | 4.7 kΩ |
| Heater Resistance (RH) | 60 ± 10 Ω |
| Heater Power Consumption (PH) | ≤ 500 mW |
| Sensitivity (2500 ppm) | S ≥ 8 |
| Concentration Slope (500/2500 ppm) | α ≤ 0.6 |
| Standard Test Conditions | 20 ± 2℃, 55% ± 5% RH, 21% O₂ |
| Preheat Time | ≥ 24 Hours |
| Service Life | ≥ 10 Years |
| Package Type | Metal Encapsulation |
4. Typical Applications
-
Home gas leak detectors
-
Industrial propane leakage alarms
-
Fire safety and security systems
-
Gas detection modules for commercial kitchens
-
OEM integration into smart safety devices
5. Precautions for Use
-
Burn-in for at least 48 hours before first use.
-
Avoid exposure to organic solvents or high-concentration gases.
-
Do not operate in corrosive gas environments for extended periods.
-
Ensure intake air does not enter perpendicularly into the sensing surface.
-
Keep the air inlet clean and unobstructed.
-
Do not use if the sensor is physically damaged or contaminated.
-
During storage, keep the working and counter electrodes short-circuited.
-
Do not encapsulate the sensor with hot-melt glue or sealants.
Conclusion
The SP11 Propane Sensor offers a reliable, efficient, and cost-effective solution for propane gas detection. Its combination of sensitivity, low power usage, and robust performance makes it a top choice for developers of gas detection systems across residential, industrial, and commercial sectors.
Interested in the SP11 Propane Sensor? Contact us now for samples, technical support, or wholesale pricing.